Output parameters of the 131I bi-phasic vs. monoexponential biokinetics model in thyroid gland

Varga F., Jirsa Ladislav

: Bratislavské lekárske listy vol.107, 4 (2006), p. 177-177

: Days of Medical Biophysics /29./, (Bratislava, SK, 16.05.2006-18.05.2006)

: CEZ:AV0Z10750506

: 1ET100750404, GA AV ČR

: thyroid activity, model of activity, effective half-life, residence time, radiation dose

(eng): Two models of time course of thyroid activity after administration of 13I were compared: bi-phasic and monoexponential. Effective half-life and time integral of activity were compared for both the models using time-activity data from 3848 patients. It was shown that the bi-phasic model gives results with higher accuracy than the monoxeponential one.

(cze): Byl porovnáván dvoufázový a monoexponenciální model časového průběhu aktivity štítné žlázy po podání 131I. Byl odhadován efektivní poločas a časový integrál aktivity pro oba modely s použitím časů a aktivit naměřených u 3848 pacientů. Bylo ukázáno, že dvoufázový model poskytuje výsledky s vyšší přesností než monoexponenciální.